Branched end layout分支端头布局
Conductors separate toward different ends, creating individual connection points. Branch lengths and directions can follow the equipment modules.导线向不同端头分出,形成独立接入位置。各支路可围绕设备模块分别安排长度与方向。
Flat-sheath signal branch harness combines branched end layout, flat conductor arrangement. Interface, circuit and installation data guide dimensions, material selection and sample review.扁平护套控制信号分支线束的结构重点包括分支端头布局、扁平排列结构。接口、电路与安装资料将作为尺寸、物料和样品制作的确认依据。
Use the flat-sheath signal branch harness form as a starting point and confirm these design points against drawings and the actual equipment.以扁平护套控制信号分支线束的结构形式为起点,结合图纸和实际设备确认以下设计要点。


Conductors separate toward different ends, creating individual connection points. Branch lengths and directions can follow the equipment modules.导线向不同端头分出,形成独立接入位置。各支路可围绕设备模块分别安排长度与方向。
The cable uses a flat arrangement, allowing compact routing around insertion direction, folds and end orientation.线缆采用扁平排列形态,可围绕插入方向、折转位置和端头朝向安排紧凑布线。
Flame retardance is not fire-resistant circuit integrity阻燃不等于耐火保持通电
The table describes the construction and available configuration choices. Materials, dimensions, circuits and inspection requirements are agreed for each project.以下说明展示结构与可配置内容。具体材料、尺寸、电路和检验要求按项目确认。
| Specified flame standard, method and class指定阻燃标准、试验方法与等级 | Specify the flame standard, test method and required classification.指定阻燃标准、试验方法及要求等级。 |
|---|---|
| Single-cable or bunched-test scope单根或成束试验适用范围 | Define single-cable or bunched testing to avoid mixing their scopes.明确单根或成束试验,避免混用适用范围。 |
| Jacket/insulation materials and specimen specification护套绝缘材料与试样规格 | Match insulation, jacket and test specimen to the supplied construction.绝缘、护套与试样规格对应实际供货结构。 |
| Test report, model and batch mapping检测报告、型号和批次对应 | Reports must map to the exact model, construction and supply batch.报告需可对应准确型号、结构和供应批次。 |
| Installation and operating boundary安装与使用边界 | Provide exact fire-test method, installation, construction, marking and evidence.请提供准确燃烧试验方法、安装、结构、印字与证据。 |
| Sample and release basis样品与放行依据 | Release records the exact cable identity and supporting fire-test evidence.放行记录包含准确线缆身份与支持燃烧试验证据。 |
These are connection directions for project discussion. Suitability depends on interfaces, circuits, installation conditions and project validation; configuration can be adapted to the equipment.以下为可讨论的连接方向。实际适用性取决于接口、电路、安装环境和项目验证,可按设备需求调整。

Coordinate terminal positions, duct exits and service access within the cabinet. Wire labels should correspond to the circuit table and equipment ports. Specify the flame standard, test method and required classification.柜内连接需协调端子位置、线槽出口和可维护空间,线号应能对应回路表与设备端口。选配时,指定阻燃标准、试验方法及要求等级。

Coordinate board positions, module removal and wire bends within the enclosure. Preserve insulation clearance and support behind each termination. Define single-cable or bunched testing to avoid mixing their scopes.机箱内部配线需要协调板卡位置、模块拆装和导线转弯空间;端接后的绝缘与支撑不能被外壳挤压。选配时,明确单根或成束试验,避免混用适用范围。

Define bends, retention points and assembly order in confined spaces. Do not compensate for an incorrect interface direction or length with forced folds. Match insulation, jacket and test specimen to the supplied construction.狭小空间布线需明确转弯、固定点和拆装顺序,不能用强行折线弥补接口方向或长度误差。选配时,绝缘、护套与试样规格对应实际供货结构。

Select power branches from actual loads, circuit protection and route length. Include termination, retention and service positions in the wiring definition. Reports must map to the exact model, construction and supply batch.供电分支以实际负载、回路保护和线长为选配依据,端头、固定和检修位置也需列入布线定义。选配时,报告需可对应准确型号、结构和供应批次。

Contact selection depends on conductor construction, insulation diameter and tooling limits. Set wire preparation and crimp inspection for the actual contact part. Specify the flame standard, test method and required classification.端子选择同时取决于导体结构、绝缘外径和工具范围;备线尺寸与压接检查应落到实际接点型号。选配时,指定阻燃标准、试验方法及要求等级。

Keep internal connections clear of working zones and moving parts. Allow appropriate cable length between supports, interfaces and service paths. Define single-cable or bunched testing to avoid mixing their scopes.设备机内连接要避开加工区与运动部件,并在固定点、接口和检修路径之间保留合理线缆余量。选配时,明确单根或成束试验,避免混用适用范围。


Our China factory supports flame-retardant cable projects through custom wire harness manufacturing and OEM/ODM development. Interface, circuit and installation data guide material selection, sample builds and manufacturing-document approval before repeat production.Super Smile-Tech 中国工厂围绕阻燃电线电缆的项目需求提供定制线束制造与 OEM/ODM 支持。我们从接口、电路与安装资料开始,协同物料选配、样品制作和制造文件确认,再按批准要求组织重复生产。
Specify the flame standard, test method and required classification. Flame retardance is not fire-resistant circuit integrity.指定阻燃标准、试验方法及要求等级。 阻燃不等于耐火保持通电。
Define single-cable or bunched testing to avoid mixing their scopes. Flame retardance is not halogen-free or low-smoke performance.明确单根或成束试验,避免混用适用范围。 阻燃不等于无卤或低烟。
Match insulation, jacket and test specimen to the supplied construction. Do not equate classifications from different test systems.绝缘、护套与试样规格对应实际供货结构。 不同试验体系等级不得直接等同。
Flame retardance is not fire-resistant circuit integrity. Specify the flame standard, test method and required classification.阻燃不等于耐火保持通电。指定阻燃标准、试验方法及要求等级。
Flame retardance is not halogen-free or low-smoke performance. Define single-cable or bunched testing to avoid mixing their scopes.阻燃不等于无卤或低烟。明确单根或成束试验,避免混用适用范围。
Do not equate classifications from different test systems. Match insulation, jacket and test specimen to the supplied construction.不同试验体系等级不得直接等同。绝缘、护套与试样规格对应实际供货结构。
Share mating interfaces, a circuit table, target lengths or a sample for the flat-sheath signal branch harness. We can use them to review configuration and sample requirements.提供扁平护套控制信号分支线束的对插接口、回路表、目标长度或参考样品,我们据此梳理选配与样品确认事项。